The value of the Solar Constant.

22 Sept 2015, 14:45
30m
Meridian Room (Royal Observatory of Belgium)

Meridian Room

Royal Observatory of Belgium

Avenue Circulaire - 3 - Ringlaan 1180 Brussels
3-Results from recent space missions

Speaker

Dr Steven Dewitte (RMIB)

Description

The determination of the absolute value of the TSI - also known as the Solar Constant - is a problem of metrology. Our new best estimate of 1362.9 +/- 0.9 W/m² at solar minimum is derived from the revised absolute value measured by the DIARAD/SOVIM instrument on the ISS in 2008. Compared to earlier versions of the DIARAD TSI evaluation we apply a new method for the determination of the so-called non-equivalence between electrical and optical power. This new evaluation method was validated during a laboratory measurement campaign at the LASP TRF facility in 2013. During this same campaign we identified an underestimation of the irradiance measured by the LASP TRF cryogenic radiometer, which after elimination of all other possible causes can only be attributed to an underestimation of the amount of scattering and diffraction occuring around the LASP TRF primary aperture. Since the TIM/SORCE space radiometer has a similar geometry and TSI evaluation method as the LASP TRF cryogenic radiometer, this suggests that the TIM/SORCE radiometer measures a too low TSI value.

Summary

The determination of the absolute value of the TSI - also known as the Solar Constant - is a problem of metrology. Our new best estimate of 1362.9 +/- 0.9 W/m² at solar minimum is derived from the revised absolute value measured by the DIARAD/SOVIM instrument on the ISS in 2008. Compared to earlier versions of the DIARAD TSI evaluation we apply a new method for the determination of the so-called non-equivalence between electrical and optical power. This new evaluation method was validated during a laboratory measurement campaign at the LASP TRF facility in 2013. During this same campaign we identified an underestimation of the irradiance measured by the LASP TRF cryogenic radiometer, which after elimination of all other possible causes can only be attributed to an underestimation of the amount of scattering and diffraction occuring around the LASP TRF primary aperture. Since the TIM/SORCE space radiometer has a similar geometry and TSI evaluation method as the LASP TRF cryogenic radiometer, this suggests that the TIM/SORCE radiometer measures a too low TSI value.

Primary author

Dr Steven Dewitte (RMIB)

Presentation materials

There are no materials yet.